Panasonic PT-D6000 User Manual

Page of 52
Settings
PROJECTOR SETUP menu
E
NGLISH - 30
You can see the status of the projector about the following 
items.
*  Not available for PT-D5000.
After you replaced the Auto Cleaning Filter (ACF), 
REMAINING FILTER of STATUS need to be reset to "0".
1. Press the ENTER button.
2. Select OK by pressing I, then press the ENTER button.
3. The REMAINING FILTER of STATUS will be reset to 
“0”.
 
Display the STATUS and confirm the figure.
You can set the timer to switch off the power of the projector 
after a certain period of time automatically when no signal is 
detected. Press I H to select the required period from 10 to 
90 minutes at intervals of 10 minutes.
You can assign a certain menu function to the FUNCTION 
button as shortcut. Press I H to select the required menu 
option, and the ENTER button.
STATUS
Items
Description
INPUT
Displays the input selection state.
NAME
Displays the input signal name.
SIGNAL FREQUENCY
Displays the frequency of the input 
signal.
PROJECTOR RUNTIME
Displays the projector runtime.
LAMP1
Displays the lighting time of LAMP1.
LAMP2
Displays the lighting time of LAMP2.
INTAKE AIR TEMP.
Displays the intake air temperature of 
the projector.
OPTICS MODULE TEMP.
Displays the temperature inside the 
projector.
AROUND LAMP TEMP.
Displays the temperature around the 
lamp of the projector.
REMAINING FILTER
Displays the filter runtime.
QUANTITY
Displays the filter remaining quantity.
PROJECTOR TYPE
Displays type of projector.
SERIAL NUMBER
Displays the serial number of the 
projector.
MAIN VERSION
Displays the main version of the 
firmware of the projector unit.
SUB VERSION
Displays the sub version of the 
firmware of the projector unit.
NETWORK VERSION
Displays the network version of the 
projector unit.
ON COUNT
POWER ON TIMES
Displays the number of times the 
power has been tuned on.
LAMP1 ON
Displays the number of times LAMP1 
has been lit.
LAMP2 ON
Displays the number of times LAMP2 
has been lit.
SHUTTER
Displays the number of times the 
shutter function has been used.
LAMP1 LOW *
Displays the LAMP1 lighting time with 
LOW setting in LAMP POWER.
HIGH *
Displays the LAMP1 lighting time with 
HIGH setting in LAMP POWER.
LAMP2 LOW *
Displays the LAMP2 lighting time with 
LOW setting in LAMP POWER.
HIGH *
Displays the LAMP2 lighting time with 
HIGH setting in LAMP POWER.
NUMBER OF ENTRY 
SIGNAL
Displays the number of registered 
signals.
REMOTE2 STATUS
Displays REMOTE 2 IN control status.
FILTER COUNTER RESET
NOTE:
• See “Replacing the Auto Cleaning Filter (ACF)” in the 
operating instructions booklet that is provided with the 
projector.
NO SIGNAL SHUT-OFF
DISABLE
FG
FG
10 MIN.
90 MIN.
FG
FG
20 MIN.
80 MIN.
FG
FG
30 MIN.
70 MIN.
FG
FG
40 MIN.
60 MIN.
FG
FG
50 MIN.
FUNCTION BUTTON
Options
Functions
Refer
DISABLE
Deactivate the FUNCTION 
button.
-
SUB MEMORY LIST
Displays the assigned SUB 
MEMORY LIST
.
SYSTEM SELECTOR
Switches SYSTEM SELECTOR 
options.
SYSTEM DAYLIGHT 
VIEW
Switches the SYSTEM 
DAYLIGHT VIEW
 setting.
FREEZE
Freezes the image.
SIDE BY SIDE
Start the SIDE BY SIDE mode.