Panasonic PT-DS8500E User Manual

Page of 129
PROJECTOR SETUP menu
76
 - ENGLISH
Settings
COOLING CONDITION
You can control the fan speed for projecting 
angle. When the projector is angled, [COOLING 
CONDITION] setting must be set correctly. Failure to 
observe this may result in malfunctions, or the life of 
the lamp or the other components may be shortened.
Press ▲▼ to select [COOLING 
1 ) 
CONDITION].
Press <ENTER> button.
2 ) 
The [COOLING CONDITION] screen will be 
 
z
displayed.
Press ▲▼ to select cooling condition.
3 ) 
Press <ENTER> button.
4 ) 
When the confirmation message is 
5 ) 
displayed, select [OK] or [CANCEL].
LAMP SELECT
You can select a lamp lighting pattern for using 
environment.
Press ▲▼ to select [LAMP SELECT].
1 ) 
Press ◄► to switch [LAMP SELECT].
2 ) 
The setting will change as follows each time 
 
z
◄► is pressed.
DUAL
SINGLE
LAMP2
LAMP1
DUAL
All lamps will light.
SINGLE
Selects a lamp with shorter duration 
of use.
LAMP1
Selects the Lamp unit 1.
LAMP2
Selects the Lamp unit 2.
Press <ENTER> button.
3 ) 
Note
If, in the [SINGLE], [LAMP1] or [LAMP2] mode, one lamp 
 
z
remains off or the currently active lamp exceeds 3 000 
hours of cumulative operating time (when [HIGH] is 
selected as the [LAMP POWER] setting), the other lamp 
will light.  
If, in the [DUAL] mode, one lamp remains off or the 
currently active lamp exceeds 3 000 hours of cumulative 
operating time (when [HIGH] is selected as the [LAMP 
POWER] setting), the other lamp alone will light.  
However, if both lamps remain off or the 3 000 hours of 
cumulative operating time (when [HIGH] is selected as 
the [LAMP POWER] setting) are exceeded, the projector 
will enter the standby mode.
The colors of the items indicate the status.
 
z
Green→Current setting
Yellow→Current setting
(when a lamp fails or fails to light)
Red→Lamp that has failed to light
White→Any other status
If the projector is repeatedly used for short periods of 
 
z
time, the lamps will need to be replaced more frequently.
LAMP RELAY
If using the projector for a continuous period of 
24 hours or more, this setting can be used to 
automatically switch the lamps that are turned on in 
order to reduce the lamp deterioration that can occur 
as a result of continuous use.
Press ▲▼ to select [LAMP RELAY].
1 ) 
Press <ENTER> button.
2 ) 
The [LAMP RELAY] screen is displayed and the 
 
z
adjustment mode (flashing) is activated.
Press ◄► to select [HOUR] or 
3 ) 
[MINUTE] and use ▲▼ to adjust the 
time.
Press <ENTER> button.
4 ) 
The lamp relay is set to the selected time.
 
z
OFF 
Û
00 : 00
00 : 59
00 : 01
When setting the [MINUTE], irrespective of the 
Û
set value for [HOUR], please adjust and set in the 
following order of 59 minutes, [OFF], 00 minutes.
CEILING  
SETTING
30°
30°
VERTICAL DOWN 
SETTING
30°
30°
VERTICAL UP  
SETTING
FLOOR  
SETTING
(Unit: 1 hour or 
1 minute)