Maintenance/replacement
58
 - ENGLISH
Maintenance
 
J
Lamp unit
The lamp unit is a consumable component. See "When to replace the lamp unit" about the lifespan.
It is recommended to ask an authorized engineer to replace the lamp unit. Contact your dealer.
Consult your dealer to purchase a replacement lamp unit. 
(for PT-CW330E / PT-CX300E: ET-LAC300; for PT-CW240E: ET-LAC200) 
CAUTION:
■ Do not replace the lamp unit when it is hot. (Wait at least 1 hour after use.)
The inside of the cover can become very hot, take care to avoid burn injuries.
 
J
Notes on the replacement of the lamp unit
The luminous source of the lamp is made of glass and may burst if you hit it against a hard surface or drop 
 
z
it. Please handle with care.
A Phillips screwdriver is required for replacement of the lamp unit.
 
z
Be careful of hands slip when you using a screwdriver.
 
z
When replacing the lamp unit, be sure to hold it by the base.
 
z
When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp may be 
 
z
broken. If replacing the lamp of a projector which has been installed on the ceiling, you should always 
assume that the lamp is broken, and you should stand to the side of the lamp cover, not underneath it. 
Remove the lamp cover gently. Small pieces of glass may fall out when the lamp cover is opened. If pieces 
of glass get into your eyes or mouth, seek medical advice immediately.
The lamp contains mercury. Consult your local municipality or your dealer about correct disposal of used 
 
z
lamp units.
Attention
Be sure to use the lamp unit specified.
 
z
Note
The part numbers of accessories and separately sold components are subject to change without notice.
 
z
 
J
When to replace the lamp unit
The lamp unit is a consumable component. Brightness decreases according to duration of usage, so 
periodical replacement of the lamp unit is necessary. The estimated duration before replacement is 3 000 
hours for PT-CW330E / PT-CX300E and 3 500 hours for PT-CW240E. However, this may be shortened 
depending on individual lamp characteristics, usage conditions, and the installation environment. Therefore, it 
is strongly recommended that a replacement lamp unit be prepared.
When the projection lamp of the projector reaches its end of life, the warning message appears on the screen. 
Replace the lamp with a new one promptly.
Model name
Lamp runtime
On screen:Warning Lamp message
PT-CW330E
PT-CX300E
Over 2 970 hours *
If the lamp is used over 2 970 hours, the warning message will 
appear. When any button is pressed, the message will disappear. 
PT-CW240E
Over 3 470 hours *
If the lamp is used over 3 470 hours, the warning message will 
appear. When any button is pressed, the message will disappear. 
Note
The lamp replace time, it is necessary to carry the following calculation. Confirm the lamp used time in the [LAMP settings] 
 
z
(
Æ
page 43). 
For PT-CW330E / PT-CX300E 
     Lamp use time=[Lamp used time (Normal)] + [Lamp used time (Eco)] × 3 ÷ 4 
For PT-CW240E 
     Lamp use time=[Lamp used time (Normal)] + [Lamp used time (Eco)] × 3.5 ÷ 5
 The usage period of 3 000 hours / 3 500 hours is a rough estimate and is not guaranteed.
 