Panasonic RS-232C User Manual

Page of 49
36/49 
 
2.109. Query DOT CLOCK 
Hexadecimal 02h 51h 44h 43h 
03h 
Character  Q D C  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 *3 *5 03h 
Character    *2 *4 *6   
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
×
 
×
 
 
 
Parameters (*1, *2, *3, *4, *5, *6) 
 
32 
31 
30 
Hexadecimal 2Dh 
33h 32h 2Dh 
33h 31h 2Dh 
33h 30h 
Character 
 3  2 - 3  1 - 3  0 
 30  31  32 
Hexadecimal 30h 33h 30h 30h 33h 31h 30h 33h 32h 
Character 0 3 0 0 3 1 0 3 2 
Note: 
• 
Only when the input is COMPUTER1 or COMPUTER2, and still image is displayed, this command is acceptable. 
In other cases, ER401 is returned. 
 
2.110. Query CLOCK PHASE 
Hexadecimal 02h 51h 43h 50h 
03h 
Character  Q C P  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 *3 *5 03h 
Character    *2 *4 *6   
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
×
 
×
 
 
 
Parameters (*1, *2, *3, *4, *5, *6) 
 
16 
15 
14 
Hexadecimal 2Dh 
31h 36h 2Dh 
31h 36h 2Dh 
31h 36h 
Character 
 1  6 - 1  6 - 1  4 
 14  15  16 
Hexadecimal 30h 31h 34h 30h 31h 35h 30h 31h 36h 
Character 0 1 4 0 1 5 0 1 6 
Note: 
• 
This command is acceptable only when the input is COMPUTER1 or COMPUTER2. In other cases, ER401 is 
returned. 
 
2.111. Query ASPECT 
Hexadecimal 02h 51h 53h 31h 
03h 
Character  Q S 1  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 03h 
Character   *2  
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
×
 
×
 
 
 
Parameters (*1, *2) 
F300 series 
 AUTO 
4:3 16:9 S4:3  THROUGH 
Hexadecimal  30h  31h 32h 33h 
34h 
Character 0 1 2 3  4 
FW300 series 
 AUTO 
4:3 
16:9 
H-FIT  V-FIT  HV-FIT  THROUGH 
Hexadecimal 30h 31h 32h 33h  34h  35h 
36h 
Character 0 1 2 3  4  5