2.112. Query FRAME LOCK 
Hexadecimal 02h 51h 46h 4Ch 
03h 
Character  Q F L  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 03h 
Character   *2  
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
×
 
×
 
 
 
Parameters (*1, *2) 
 OFF 
ON 
Hexadecimal 30h  31h 
Character 0 1 
 
2.113. Query LANGUAGE 
Hexadecimal 02h 51h 4Ch 47h 
03h 
Character   Q L G  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 *3 *5 03h 
Character    *2 *4 *6   
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
 
 
 
 
Parameters (*1, *2, *3, *4, *5, *6) 
 English German French 
Hexadecimal 45h 4Eh 47h 44h 45h 55h 46h 52h 41h 
Character  E N G D E U F R A 
 Spanish  Italian Japanese 
Hexadecimal 45h 53h 50h 49h 54h 4Ch 
4Ah 
50h 4Eh 
Character E S P I T L J P N 
 Chinese Russian Korean 
Hexadecimal 43h 48h 49h 52h 55h 53h 4Bh 
4Fh 52h 
Character  C H  I  R U S K O R 
 Portuguese Swedish Norwegian 
Hexadecimal 50h 4Fh 52h 53h 56h 45h 4Eh 
4Fh 52h 
Character  P O R S V E N O R 
 Danish  Polish  Czech 
Hexadecimal 44h 41h 4Eh 
50h 4Fh 4Ch 
43h 45h 53h 
Character  D A N P O L C E S 
 Hungarian  Thai 
Hexadecimal 4Dh 
41h 47h 54h 48h 41h 
Character M A G T H A 
 
2.114. Query INPUT GUIDE 
Hexadecimal 02h 51h 44h 49h 
03h 
Character  Q D I  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 03h 
Character   *2  
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
 
 
 
 
Parameters (*1, *2) 
 OFF 
SIMPLE 
DETAILED 
Hexadecimal 30h  31h 
32h 
Character 0  1