Panasonic RS-232C User Manual

Page of 49
45/49 
 
2.141. Query SCREEN FORMAT 
Hexadecimal 
02h 51h 53h 
 46h 03h 
Character 
 Q S F  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 03h 
Character   *2  
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
×
 
 
 
 
Parameters (*1, *2) 
 16:10 
16:9 
Hexadecimal 30h  31h 
Character 0  1 
Note: 
• 
This command is acceptable only for PT-FW300 series. In other models, ER401 is returned. 
 
2.142. Query OVER SCAN 
Hexadecimal 
02h 51h 4Fh 
 56h 03h 
Character 
 Q O V  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 03h 
Character   *2  
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
×
 
×
 
 
 
Parameters (*1, *2) 
 
0% 
3% 
5% 
7% 
Hexadecimal 
30h 31h 32h 33h 
Character 
0 1 2 3 
 
2.143. Query VGA60/480p setting 
Hexadecimal 
02h 51h 56h 
 35h 03h 
Character 
 Q V 5  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 03h 
Character   *2  
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
×
 
×
 
 
 
Parameters (*1, *2) 
 VGA60 
480p 
AUTO 
Hexadecimal  30h 31h 32h 
Character  0 1 2 
 
2.144. Query DIGITAL CINEMA REALITY 
Hexadecimal 
02h 51h 50h 
 44h 03h 
Character 
 Q P D  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 03h 
Character   *2  
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
×
 
×
 
 
 
Parameters (*1, *2) 
 OFF 
ON 
Hexadecimal 30h 31h 
Character 0 1 
Note: 
• 
This command is available only when an interlaced signal is inputted. In other cases, ER401 is returned.