Panasonic RS-232C User Manual

Page of 49
47/49 
 
2.148. Query SCREEN POSITION 
Hexadecimal 02h  51h  56h  58h 3Ah 
59h 53h 50h 49h 31h 
Character  Q V X : V S P I 1 
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h 59h 53h 50h 49h 31h 3Dh 2Dh 
Character  V S P I 1 = + 
Hexadecimal *1 *3 *5 *7 *9 03h 
Character  *2 *4 *6 *8 *10   
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
 
 
 
 
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10) 
 LOW 
Hexadecimal 30h  30h  30h  30h  30h 
Character 0  0  0 0 0 
 CENTER 
Hexadecimal 30h  30h  30h  30h  31h 
Character 0  0  0 0 1 
 HIGH 
Hexadecimal 30h  30h  30h  30h  32h 
Character 0  0  0 0 2 
Note: 
• 
This command is acceptable only for PT-FW300 series. In other models, ER401 is returned. 
 
2.149. Query RUNTIME - PROJECTOR 
Hexadecimal 02h  51h  56h  58h 3Ah 
52h 54h 4Dh 
49h 30h 
Character  Q V X : R T M I 0 
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal  02h 52h 54h 4Dh 49h 30h 3Dh 2Dh 
Character  R T 
M I 0 = + 
Hexadecimal *1 *3 *5 *7 *9 03h 
Character  *2 *4 *6 *8 *10   
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
 
 
 
 
Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10) 
Example: 55 hours 
Hexadecimal 30h  30h  30h  35h  35h 
Character 0  0  0 5 5