Cabletron Systems DLE23-MA User Manual

Page of 202
Chapter 3: Installation
3-8
DLE22-MA, DLE32-MA, DLE23-MA and DLE33-MA User’s Guide
3.5.2
Connecting UTP Cables to Ports 1 Through 24 of 
the DLE33-MA and DLE23-MA
When facing the front panel of the DLE33-MA or DLE23-MA, the upper 
RJ21 is the connector for 10BASE-T ports 1 through 12. The lower RJ21 
is for 10BASE-T ports 13 through 24. All 24 ports have internal 
crossovers.
Connect a twisted pair segment to the DLE33-MA and DLE23-MA as 
follows:
1.
Ensure that the device connected to the other end of the segment is 
powered ON.
2.
If using an RJ21 straight connector, plug it into the appropriate RJ21 
port as shown in Figure 3-4 or, if using the RJ21 angle adapter 
supplied with the device, insert the RJ21 angle adapter as shown in 
Figure 3-5. The RJ21 angle adapter allows the cable to be inserted 
without interfering with the proper attachment of the second 
connector.
.
Figure 3-4
DLE33-MA and DLE23-MA Twisted Pair Connection
14
13
9
10
11
12
15
16
17
18
19
20
21
22
23
24
RX (Receive)
LED
LKG-10874-98F
Screw
Screw Hole
Screw Hole
Screw
24
13
1