Cabletron Systems 9C300-1 User Manual

Page of 50
A-3
EPIM-F1 and EPIM-F2
Table A-2. Transmitter Power 
Parameter
Typical Value
Worst 
Case
Worst Case 
Budget
Typical 
Budget
50/125 
µ
fiber
-13.0 dBm
-15.0 dBm
13.0 dB
17.5 dB
62.5/125 
µ
fiber
-10.0 dBm
-12.0 dBm
16.0 dB
20.5 dB
100/140 
µ
fiber
-7.0 dBm
-9.0 dBm
19.0 dB
23.5 dB
Error Rate
Better than 10
-10
The transmitter power levels and receive sensitivity levels listed are Peak Power 
Levels after optical overshoot. A Peak Power Meter must be used to correctly 
compare the values given above to those measured on any particular port. If 
Power Levels are being measured with an Average Power Meter, then 3 dBm 
must be added to the measurement to correctly compare those measured values 
to the values listed (i.e., -30.5 dBm peak = -33.5 dBm average).
NOTE