Cabletron Systems 9C300-1 User Manual

Page of 50
EPIM Specifications
A-4
EPIM-F3
The EPIM-F3 supports Single Mode Fiber Optic cabling. It has an internal 
Cabletron Systems FOT-F™ Fiber Optic Transceiver and is equipped with ST 
Connectors. Figure A-3 shows the EPIM-F3. Specifications for the EPIM-F3 ar
listed in Figure A-4 and Table A-3.
Figure A-3. EPIM-F3
Figure A-4. EPIM-F3 Power and Sensitivity Specifications
Receive
Sensitivity
dBm
Less Power
More Power
-40
-35
-30
-25
-20
-15
-10
-5
0
Maximum
Receive
Input Power
Transmitter Power*
(At 25
°
C into
8.3/125
µ
m fiber)
Minimum Sensitivity (-30.0)
Typical Sensitivity (-31.0)
Maximum Sensitivity (-36.0)
Maximum Receive Input (-6.99)
Typical Receive Input (-7.5)
Minimum Receive Input (-9.72)
Maximum Transmit Power (-12.0)
Typical Transmit Power (-15.5)
Minimum Transmit Power (-21.0)
*  Transmit Power   
Typical Power  
Minimum Power  
Maximum Power
     Coefficient
(See Note Below) 
-0.15dBm/
°
C  
-0.12 dBm/
°
C  
-0.18  dBm/
°
C
Transmitter Power decreases as temperatures rise and increases as 
temperatures fall. Use the Output Power Coefficient to calculate increased or 
decreased power output for your operating environment. For example, the 
typical power output at 25
°
C is -16.4 dBm. For a 4
°
C temperature increase, 
multiply the typical coefficient (-0.15 dBm) by four and add the result to typical 
output power (4 x -0.15 dBm + -16.4 = -17.0).
NOTE