Cabletron Systems SEH-22 User Manual

Page of 56
CHAPTER 2: INSTALLATION REQUIREMENTS/SPECIFICATIONS
2-6
SEH USER’S GUIDE
Fault Protection:
Each segment disconnects itself 
from the other segments if 32 
consecutive collisions occur, or if 
the collision detector of a segment 
is on for longer than approximately 
110 
µ
s. This fault protection resets 
automatically after one packet is 
transmitted or received onto the 
fault protected segment without 
causing a collision.
Power Requirements
The SEH uses a universal power supply. The input power requirements 
are listed below.
The power supply has two outputs of +5 Vdc and +12 Vdc. The maximum 
output power is 20 W and the minimum efficiency is 65% under all 
conditions of line at full load.
Environmental Requirements
Operating Temperature:
+5
°
 to +50
°
C
(41
°
 to 122
°
F)
Non-operating Temperature:
-30
°
 to +90
°
C
(-22
°
 to 194
°
F)
Operating Humidity:
5% to 95% (non-condensing)
Table 2-1. Power Requirements
Model
Voltage Range
Frequency 
Range
SEH-22/SEH-24
100-125 VAC
or
200-240 VAC
50-60 Hz
SEH Book  Page 6  Tuesday, March 19, 1996  4:12 PM