Cisco Systems SFS 3012 User Manual

Page of 79
15
NOTE: The power socket on the back (service end) of the Topspin 360 corresponds to the power 
supply module on the same side of the Server Switch.
Removing a Power Supply
To remove the power supply, perform the following steps:
1. Remove the power cord from the power supply.
2. Disengage the power supply by pulling it toward you.
3. Slide the power supply out of the chassis.
4. Fasten a blanking panel to the empty chassis bay to ensure appropriate cooling. 
NOTE: The blanking panel is a flat sheet of metal with the same dimensions as the power module 
faceplate.
Blower Trays
The hot-swappable blower trays (fans) of your Topspin 360 maintain the internal temperature of your 
Server Switch. You do not need to turn off power to the chassis to replace a blower tray. Access the 
blower tray from the front (bezel end) of the Topspin 360 chassis. 
 displays the blower trays 
in the chassis.
Figure 2-11: Blower Trays
NOTE: Your chassis requires two fully-functioning blower modules at all times.
Install Blower Trays
To insert a blower tray, perform the following steps:
1. Ground yourself appropriately.
2. Remove the blower tray from any packaging.
Blower Tray
Blower Tray