DELL S50V User Manual

Page of 1262
418
|
Interfaces
www.dell.com | support.dell.com
Figure 20-3.  Interfaces listed in the show running-config Command (Partial)
Enable a Physical Interface
After determining the type of physical interfaces available, the user may enter the INTERFACE mode by 
entering the command 
interface interface slot/port
 to enable and configure the interfaces. 
To enter the INTERFACE mode, use these commands in the following sequence, starting in the 
CONFIGURATION mode: 
Step
Command Syntax
Command Mode
Purpose
1
interface
 
interface
CONFIGURATION Enter 
the 
keyword 
interface
 followed by the type of interface 
and slot/port information:
For a 10/100/1000 Ethernet interface, enter the keyword 
GigabitEthernet
 followed by the slot/port information.
For a Gigabit Ethernet interface, enter the keyword 
GigabitEthernet
 followed by the slot/port information.
For the Management interface on the RPM, enter the 
keyword 
ManagementEthernet
 followed by the slot/port 
information.
For a SONET interface, enter the keyword 
sonet
 followed 
by slot/port information. 
For a 10 Gigabit Ethernet interface, enter the keyword 
TenGigabitEthernet
 followed by the slot/port 
information.
2
no shutdown
INTERFACE
Enter the 
no shutdown
 command to enable the interface. If 
the interface is a SONET interface, enter the 
encap ppp
 
command to enable PPP encapsulation.
FTOS#show running
Current Configuration ...
!
interface GigabitEthernet 9/6
 no ip address
 shutdown
!
interface GigabitEthernet 9/7
 no ip address
 shutdown
!
interface GigabitEthernet 9/8
 no ip address
 shutdown
!
interface GigabitEthernet 9/9
 no ip address
 shutdown