DELL 9.8(0.0) User Manual

Page of 1910
Version
Description
7.5.1.0
Introduced on the C-Series.
pre-6.2.1.1
Introduced on the E-Series.
Usage 
Information
Untagged interfaces can only belong to one VLAN.
In the Default VLAN, you cannot use the no untagged interface command. To 
remove an untagged interface from all VLANs, including the Default VLAN, enter 
INTERFACE mode and use the no switchport command.
Related 
Commands
Far-End Failure Detection (FEFD)
The Dell Networking operating software supports far-end failure detection (FEFD) on the Ethernet 
interfaces of the S4820T platform.
The FEFD feature detects and reports far-end link failures.
• FEFD is not supported on the Management interface.
• During an RPM failover, FEFD is operationally disabled for approximately 8 to 10 seconds.
• By default, FEFD is disabled.
debug fefd
Enable debugging of FEFD.
S4820T 
Syntax
debug fefd {events | packets} [interface]
To disable debugging of FEFD, use the no debug fefd {events | packets} 
[interface] command.
Parameters
events
Enter the keyword events to enable debugging of FEFD 
state changes.
packets
Enter the keyword packets to enable debugging of FEFD to 
view information on packets sent and received.
interface
(OPTIONAL) Enter the following keywords and slot/port or 
number information:
Layer 2