Usage 
Information
The polling interval for an interface is the maximum number of seconds between 
successive samples of counters sent to the collector. This command changes the 
global default counter polling (20 seconds) interval. You can configure an interface 
to use a different polling interval.
Related 
Commands
sflow polling-interval (Interface)
Set the sFlow polling interval at an interface (overrides the global-level setting.)
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval 
command.
Parameters
interval value
Enter the interval value in seconds. The range is from 15 to 
86400 seconds. The default is the global counter polling 
interval.
Defaults
The same value as the current global default counter polling interval.
Command 
Modes
INTERFACE
Command 
History
This guide is platform-specific. For command information about other platforms, 
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
Description
9.7(0.0)
Introduced on the S6000-ON.
9.0.2.0
Introduced on the S6000.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
8.2.1.0
Introduced on S-Series Stacking.
8.1.1.0
Introduced on the E-Series ExaScale.
7.7.1.0
Introduced on the S-Series.
7.6.1.0
Introduced on the C-Series.
7.4.1.0
Introduced on the E-Series.
sFlow