Raritan Computer 4.7 User Manual
Chapter 8: P2ZCIMs and Z-CIMs
134
7. Press
Enter and type RefreshPZ.
8. Press
Enter again.
9. Press
S to refresh the chain.
10. Press F2 to go to the Selection Menu and verify that channel order of
the chain has been refreshed.
Important: Please follow the guideline here to ensure that there is
enough power to support all P2ZCIMs in a chain.
enough power to support all P2ZCIMs in a chain.
For Paragon I UMT242, 442, 832 and 1664 with hardware III and
Paragon II firmware, and Paragon II switches, in chains up to 20
individual P2ZCIM units at least one P2ZCIM must be powered ON;
in P2ZCIM chains from 21 to 42 P2ZCIM units, at least 15 P2ZCIMs
must be powered ON.
Paragon II firmware, and Paragon II switches, in chains up to 20
individual P2ZCIM units at least one P2ZCIM must be powered ON;
in P2ZCIM chains from 21 to 42 P2ZCIM units, at least 15 P2ZCIMs
must be powered ON.
P2ZCIM LED Status
The LED on each P2ZCIM indicates its operational state:
If the LED blinks rapidly: P2ZCIM does not have a confirmed
Communication Address.
Communication Address.
If the LED is primarily off and blinks on every two (2) seconds:
P2ZCIM has a confirmed Communication Address but is not
switched to that Address.
P2ZCIM has a confirmed Communication Address but is not
switched to that Address.
If the LED is on and blinks on/off rapidly when there is
keyboard/mouse traffic: CIM has a confirmed Communication
Address and is switched to that Address.
keyboard/mouse traffic: CIM has a confirmed Communication
Address and is switched to that Address.
Note: The P2ZCIM blinks from time to time even if there is no
keyboard/mouse traffic, which demonstrates that the P2ZCIM is
operating normally and not locked.
keyboard/mouse traffic, which demonstrates that the P2ZCIM is
operating normally and not locked.