Raritan Computer 4.7 User Manual

Page of 257
 
Chapter 12: Firmware Upgrade 
 
 
183
 
STEP (D): Launch the Paragon Update Utility 
After the hardware connection is completed, you can execute the 
Paragon Update utility to upgrade the firmware. Note that Paragon 
Update version 2.4.4 or later supports this firmware upgrade. Earlier 
versions do not have this capability. Please use the latest version of the 
Paragon Upgrade utility which you downloaded along with the HubPac 
firmware to ensure the success of the upgrade. 
Prior to the firmware update with Paragon Update, ensure the 
P2-HubPac is turned on. 
 
To launch the Paragon Update utility 
1.  Double click “ParagonUpdate_xxx.exe” (xxx represents the version). 
The Paragon Update window appears. 
2.  Specify the device information of the connected HubPac. 
a.  Type a name for the HubPac in the Name field. 
b.  Select <Default Serial> in the IP address/Serial field. 
c.  Type the COM port number that your PC assigns to the HubPac 
in the Port field. 
 
3.  Select the checkbox ( 
) beside the HubPac device. 
4. Click 
Load Hex File and navigate to select the appropriate firmware 
file. 
5. Click 
Send To Paragon
6. Click 
Yes. The utility starts to upgrade the “connected cluster” of the 
HubPac. 
7.  When the connected cluster is upgraded successfully, the “Device 
Update Successful” message appears. 
Keep the Paragon Update window open if other clusters of the same 
HubPac are not upgraded yet. See the subsequent section for more 
information. 
For more details of the Paragon Update utility, see Paragon Manager 
User Guide