Chapter 12: Firmware Upgrade 
 
184
 
 
STEP (E): Repeat Steps (B) and (D) for the Other Clusters 
After finishing the upgrade of one cluster, continue to upgrade the 
remaining clusters.   
 
To upgrade the other clusters, repeat the following procedure 
on each cluster 
1.  Disconnect the Cat5 cable attached with the USB-to-RS485 cable 
from the HubPac cluster on which the upgrade has finished. 
2.  Reconnect the Cat5 cable to the server connection port of “another 
cluster” on the same HubPac, as described in 
STEP (B): Connect 
One Cluster of the HubPac to the PC
 (on page 177). 
3. Click 
Send to Paragon in the Paragon Update window to upgrade 
the connected cluster. The procedure is the same as those 
described in 
STEP (D): Launch the Paragon Update Utility
 (on 
page 183). 
Upon upgrading 8 clusters successfully, the P2-HubPac firmware update 