Chapter 2
Setup and Configuration
2-14
ni.com
4.
When the installation splash screen appears, click Install NI-IMAQ 
for IEEE 1394 Cameras
, and follow the setup instructions.
5.
Restart the development computer.
Configuring the IP Address on the CVS-1450 Device
Complete the following steps to set up an IP address and download 
software onto the CVS-1450 device.
1.
Launch Vision Builder AI on the development computer by navigating 
to Start»Programs»National Instruments»Vision Builder AI.
2.
Expand the Execution Target drop-down listbox, and click Select 
Network Target
. This process takes several seconds.
3.
In the Select Remote Target window, click 192.168.10.12 to highlight 
the row. This IP address is assigned to all unconfigured CVS-1450 
devices. 
Tip
To uniquely identify unconfigured CVS-1450 devices, connect and configure one 
CVS-1450 device at a time.
4.
Click Configure to launch the Vision Builder AI Remote Target 
Configuration Wizard.
5.
In the Identification window, enter a name for the CVS-1450 device 
in the Name field and a description of the CVS-1450 device in the 
Description field.
Note
Device names are limited to 15 characters with no spaces or special characters. 
The first and last characters must be alphanumeric.
6.
Click Next.
7.
If the network is configured to issue IP addresses using DHCP, select 
Obtain IP address from DHCP server. Otherwise, set the IP address 
manually by selecting Edit IP SettingsSuggest Values, and OK.
8.
Click Next. This window shows the status of the software installed on 
the CVS-1450 device.
9.
Select the Update Target Software checkbox.
10. Click OK to begin configuring the IP address and downloading 
software onto the CVS-1450 device. This initialization process takes 
several minutes.