National Instruments NI CVS-1450 Series User Manual

Page of 91
Chapter 4
Digital I/O Functionality
4-2
ni.com
TTL Inputs and Outputs
TTL is a fast-switching, 5 V, digital, signaling standard commonly used 
for applications that require high precision, such as camera triggering. 
TTL inputs and outputs do not require a separate power supply.
Caution
Do not connect voltage or current sources to TTL outputs. Doing so could 
damage the CVS-1450 device.
Table 4-1 summarizes the TTL inputs and outputs available on the 
CVS-1450 device. 
Isolated Inputs and Outputs
The isolated inputs and outputs on the CVS-1450 device have a separate 
ground reference from the main CVS-1450 device supply, providing an 
easy means to prevent ground loops that can introduce noise into a system. 
You can apply signals up to 30 V to the isolated inputs. The voltage swing 
of the isolated outputs is determined by the Viso you supply on the 
connector.
Note
The isolated outputs have current-limiting protection circuitry. If this circuitry is 
tripped, you can re-enable the outputs by restarting the CVS-1450 device or by toggling 
the output state in the software.
Table 4-1.  TTL Inputs and Outputs
Primary
Function
Input or 
Output
Number 
Available
Signal Names
44-Pin DSUB
on CVS-1450 
Device 
Pin Number
37-Pin 
Terminal Block 
Pin Number
Trigger
Input
2
TTL Input 0
TTL Input 1
1
16
1
2
Timed Pulse
Output
6
TRIG 1, Pulse 5
TRIG 2, Pulse 6
TTL Output 1, Pulse 1
TTL Output 2, Pulse 2
TTL Output 3, Pulse 3
TTL Output 4, Pulse 4

4
6
7
18

5
7
8
20
Watchdog
Output
1
TTL Output 0
3
4
General-Purpose
Output
3
TTL Output 5
TTL Output 6 
TTL Output 7
19
21
22
21
23
24