National Instruments NI CVS-1450 Series User Manual

Page of 91
Chapter 4
Digital I/O Functionality
© National Instruments Corporation
4-3
Table 4-2 summarizes the isolated inputs and outputs available on the 
CVS-1450 device.
I/O for Normal Operation
The following sections describe I/O functions that are available on the 
CVS-1450 device during normal operation.
Trigger Inputs
Trigger inputs are available from both TTL inputs and isolated inputs. You 
can use these trigger inputs to synchronize the CVS-1450 device with an 
external event, such as the assertion of a signal generated by a proximity 
sensor or a PLC to indicate that an inspection item is passing in front of the 
camera. The CVS-1450 device uses this input to initiate a timed pulse that 
can be used for camera control, lighting control, encoder pulse counting, 
and result output timing.
Table 4-2.  Isolated Inputs and Outputs
Primary Function
Input or 
Output
Number 
Available
Signal Names
44-Pin DSUB
on CVS-1450 
Device 
Pin Number
37-Pin 
Terminal Block 
Pin Number
Trigger
Input
3
TRIG 0
ISO Input 5
ISO Input 8

35
40

15
27
Quadrature Encoder
Input
1
ISO Input 6
ISO Input 7
37
38
25
26
External Shutdown 
Control
Input
1
ISO Input 11
44
31
Product Selection Port
Input
1
ISO Input 0
ISO Input 1
ISO Input 2
ISO Input 3
ISO Input 4
15
30
31
32
34
9
10
11
13
14
General-Purpose
Input
2
ISO Input 9 
ISO Input 10
41
43
29
30
General-Purpose
Output
4
ISO Output 0
ISO Output 1
ISO Output 2
ISO Output 3
12
13
27
28
19
35
36
37
 ISO Input 5 can also function as a latch for the product selection port.