3com 4500 26-PORT User Manual

Page of 466
400
C
HAPTER
 12: U
SING
 S
YSTEM
 M
ANAGEMENT
 C
OMMANDS
falling-threshold threshold-value2:
 Falling threshold, ranging from 0 to 
2147483647.
event-entry2:
 Event number corresponding to the falling threshold, ranging 
from 0 to 65535.
owner 
text:
 Specifies the creator of the alarm. Length of the character string 
ranges from 1 to 127.
Description
Use the 
rmon alarm
 command to add an entry to the alarm table. Use the 
undo 
rmon alarm
 command to delete an entry from this table.
In this way, the alarm event can be triggered in the abnormal situations and then 
decides to log and send trap to the NM station.
Example
Delete the information of entry 15 from the alarm table.
<SW4500>system-view
System View: return to User View with Ctrl+Z.
[SW4500]undo rmon alarm 15
[SW4500]
rmon event
Syntax
rmon event event-entry [ description string
 ] { log | trap 
trap-community | log-trap log-trapcommunit
y | none } [ owner 
rmon-station ]
undo rmon event event-entry
View
System view
Parameter
event-entry:
 Number of the entry to be added/deleted, ranging from 1 to 
65535.
description string:
 Event description. Length of the character string ranges 
from 1 to 255.
log:
 Log event.
trap:
 Trap event.
trap-community: 
The community of the Network Management station that the 
trap message is sent to.
log-trap:
 Log and trap event.
log-trapcommunity: 
The community of the Network Management station that 
the trap message is sent to.
none:
 neither log nor trap event.