3com 4500 26-PORT User Manual

Page of 466
402
C
HAPTER
 12: U
SING
 S
YSTEM
 M
ANAGEMENT
 C
OMMANDS
[SW4500]interface Ethernet1/0/1
[SW4500-Ethernet1/0/1]undo rmon history 15
[SW4500-Ethernet1/0/1]
rmon prialarm
Syntax
rmon prialarm entry-number alarm-var alarm-des ]
 sampling-timer { 
delta | absolute | changeratio } rising-threshold threshold-value1 
event-entry1 falling-threshold
 threshold-value2 event-entry2 
entrytype { forever | cycle cycle-period
 } [ owner text ]
undo rmon prialarm entry-number
View
System view
Parameter
entry-number: 
Specifies the entry number, ranging from 1 to 65535.
alarm-var:
 Specifies the alarm variable, which can be an arithmetic expression of 
several integer MIB node instances. The node can be OID in dotted notation.
alarm-des:
 Specifies the alarm description with a length ranging from 0 to 
0-127; 
sampling-timer:
 Sets the sampling interval, ranging from 10 to 65535 and 
measured in seconds.
delta | absolute | changeratio:
 Specifies the sampling type as delta ratio or 
absolute ratio.
threshold-value1:
 Rising threshold value, specified with a number greater than 
0.
event-entry1:
 Corresponding event number to the upper limit threshold value, 
ranging from 0 to 65535.
threshold-value2:
 Falling threshold value, specified with a number greater than 
0.
event-entry2:
 Event number corresponding to the falling threshold, ranging 
from 0 to 65535.
forever | cycle cycle-period:
 Specifies the type of the alarm instance line.
cycle-period
 specifies the functional cycle of the instance.
owner text:
 Specifies the creator of the line. Length of the character string 
ranges from 1 to 127.
Description
Use the 
rmon prialarm
 command to add an entry to the extended RMON alarm 
table. Use the 
undo rmon prialarm
 command to delete an entry from the 
extended RMON alarm table.