Transmit Queues Configuration Screen
9-14
802.1p Configuration Menu Screens
Field Descriptions
Refer to 
 for a functional description of each screen field.
Table 9-5
Transmit Queues Configuration Screen Field Descriptions
Use this field …
To…
Current Queueing 
Mode
 
(Toggle)
Toggle between the STRICT 802.1 and WEIGHTED mode. The default 
setting is STRICT 802.1. To set the mode, refer to 
Weights Q0, Q1, 
Q2, Q3 
(Selectable)
Allocate the percentage of port transmission capacity according to 
transmit queues Q0 through Q3 (with Q0 being the lowest priority 
transmit queue).
NOTE: These selectable fields (Q0 through Q3) do not 
display when the Current Queueing Mode is set to STRICT 
802.1.
The weights selected must equal 100% or the values cannot be saved. 
Default weight distribution is 25% per transmission queue. Selectable 
percent weight values per priority transmit queue Q0 through Q3 are as 
follows: 00, 06, 12, 19, 25, 31, 38, 44, 50, 56, 62, 69, 75, 81, 88, 94, 
100. To set the weight per priority, refer to 
.
Port 
(Selectable)
Step to the port to be configured. As each port is stepped to, the port 
type (e.g., Ethernet front panel) displays to the right of the selected port 
number. To display the current weight settings for the selected port, 
press ENTER.
Number of Queues 
(Read-Only)
See the number of Queues.
SET ALL PORTS 
(Command)
Set all available ports to the current screen settings.
NOTE: These selectable fields (Q0 through Q3) do not 
display when the Current Queueing Mode is set to STRICT 
802.1.