14.5.4.24
Buffer Manager Port 1 Ingress Rate Drop Count Register (BM_RATE_DRP_CNT_SRC_1)
This register counts the number of packets received on Port 1 that were dropped by the Buffer
Manager due to ingress rate limit discarding (Red and random Yellow dropping).
Manager due to ingress rate limit discarding (Red and random Yellow dropping).
Register #:
1C17h
Size:
32 bits
BITS
DESCRIPTION
TYPE
DEFAULT
31:0
Dropped Count
These bits count the number of dropped packets received on Port 1 and is
cleared when read.
These bits count the number of dropped packets received on Port 1 and is
cleared when read.
Note:
This counter will stop at its maximum value of FFFF_FFFFh.
Minimum rollover time at 100Mbps is approximately 481 hours.
Minimum rollover time at 100Mbps is approximately 481 hours.
RC