Product Characteristics 
 
4.2 SCALANCE X208 
Device startup, the LED is lit for approx. 6s. 
Ports 1 through 8 LED flash yellow  Setting or display of the fault mask 
Port 1 through 8 LED flashes green The "Show Location" function was activated over Ethernet (e.g. 
PST tool). 
PROFINET IO operation was started with the PN IO controller, 
the attempt to change the fault mask with the button was 
rejected by all the port LEDs flashing once. 
The button was pressed for longer than 15 s to reset the 
configuration. 
LED Display during Startup 
Following startup, the following LEDs light up in the following order: 
•  Power LEDs (green) light up immediately after turning on the power. 
•  Port LEDs (yellow) light up for approx. 6 s, the red LED is off. 
•  Port LEDs go off, the red LED is lit for approx. 20 s. 
After the port LEDs go off, the correct link status is displayed after approx. 2 s. 
The device is now ready for operation. 
4.2.9 
SCALANCE X208 Technical Specifications 
Technical Specifications of the SCALANCE X208 
 
Ports 
Attachment of DTEs or network components over 
twisted pair 
8 x RJ-45 sockets with MDI-X pinning 10/100 
Mbps (half/ full duplex) 
Connector for power supply 
1 x 4-pin plug-in terminal block 
Connector for signaling contact 
1 x 2-pin plug-in terminal block 
Electrical Data 
Power supply 
2 x 24 V DC 
(18 - 32 V DC) 
safety extra-low voltage (SELV) 
Power loss at DC 24 V 
4.4 W 
Current consumption at rated voltage 
185 mA 
Overvoltage protection at input 
PTC resetable fuse (0.6 A / 60 V) 
Permitted Cable Lengths 
Network span parameter/TP cable length 
0 – 100 m 
 
 
 
0 – 85 m 
 
IE FC standard cable with IE FC RJ-45 plug 180 
or  
over IE FC outlet RJ-45 with 0 - 90 m IE FC 
standard cable + 10 m TP cord  
IE FC marine/trailing cable with IE FC RJ-45 plug 
180  
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line 
Commissioning Manual, 1,   