Siemens X-200 User Manual

Page of 121
Product Characteristics 
 
4.2 SCALANCE X208 
or 
0 - 75 m IE FC marine/trailing cable + 10 m TP 
cord 
Aging time 
Aging time 
5 minutes 
 
 
Permitted Environmental Conditions / EMC 
Operating temperature 
-20° C through +70° C 
Storage/transport temperature 
-40° C through +80° C 
Relative humidity in operation 
‹ 95% (no condensation) 
Operating altitude 
2000 m at max 56 °C ambient temperature 
3000 m at max. 50 °C ambient temperature 
RF interference level 
EN 50081-2 Class A 
Noise immunity 
EN 50082-2 
Degree of protection 
Tested to IP30 
Approvals 
UL 60950 
c-UL-us 
CSA C22.2 No. 60950 
c-Ul-us for hazardous locations  
UL 1604, UL 2279Pt.15 
FM 
FM 3611 
C-TICK 
AS/NZS 2064 (Class A). 
CE 
EN 50081-2, EN 50082-2 
ATEX Zone 2 
EN50021 
MTBF 
MTBF 
25.56 years 
Construction 
Dimensions (W x H x D) in mm 
60 x 125 x 124 
Weight in g 
780 
Installation options 
DIN rail  
S7-300 standard rail  
Wall Mounting 
Order Numbers 
SCALANCE X208 
6GK5208-0BA00-2AA3 
"Industrial Ethernet TP and Fiber Optic Networks" 
manual 
6GK1970-1BA10-0AA0 
IE FC Stripping Tool 
6GK1901-1GA00 
IE FC blade cassettes 
6GK1901-1GB00 
IE FC TP standard cable 
6XV1840 2AH10 
IE FC TP trailing cable 
6XV1840-3AH10 
IE FC TP marine cable 
6XV1840-4AH10 
IE FC RJ-45 Plug 180 pack of 1 
6GK1 901-1BB10-2AA0 
IE FC RJ-45 Plug 180 pack of 10 
6GK1 901-1BB10-2AB0 
IE FC RJ-45 Plug 180 pack of 50 
6GK1 901-1BB10-2AE0 
 
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line 
4-16
 