Siemens DataNET Hub (DNH) User Manual

Page of 97
 
2000585-001 
Installation 
••••  19 
Site Wiring Requirements 
How you wire to the DNH is dependent upon the site requirements: 
•  CE (Conformite Europeene) Certified Areas 
•  NEC Division 2 or Non-Hazardous Areas 
•  Cenelec Zone 1 or Zone 2 Areas 
•  Rack Mounting Non-Hazardous Area 
 
The installation should have a power disconnect external to HUB enclo-
sure. 
No voltage dependent selections need to be made on the HUB power 
supply, as it has a universal input.  
See Page 23, CE Installations. 
Use Metal Conduit wiring method. 
Conductor type: Power cable sized for circuit protection chosen. 
Use Cable Gland wiring method: 
Conductor type: Power cable sized for circuit protection chosen, and 
must be shielded. 
Use Metal Conduit wiring method.  
Conductor type: Power cable sized for circuit protection chosen. 
Description 
Wiring of Power to 
DataNET HUB 
CE Installations 
NEC Div 1, Div 2 or Non 
Rated Areas  
Cenelec Zone 1 or Zone 2 
Rated Areas 
Non Rated Areas or Rack 
Mounting