GarrettCom 500-Series User Manual

Page of 34
Magnum 500-Series Switching Hubs
Installation and User Guide (08/98)
GARRETT
2
Fiber Optic Interface
100Mb/s   Single-mode Port
Optical
Typical
Worst
Wavelength
1300nm
-----
Transmitter output power
-11.5dBm
-15.5dBm
Receiver sensitivity
-32dBm
----
Fiber Optic cable type
9/125
µ
m single-mode
Saturation
-8dBm
Max. Distance
15Km full-duplex       (412m HDX, PDV limit)
100Mb/s   Multi-mode Port
Optical
Typical
Worst
Wavelength
1300nm
-----
Transmitter output power
-16.5dBm
-19.5dBm
Receiver sensitivity
-23.5dBm
-32.5dBm
Fiber Optic cable type
62.5/125
µ
m multi-mode
Saturation
-14dBm
Max. Distance
2Km full-duplex         (412m HDX, PDV limit)
LEDs:
PWR (AC power),  LK/RX (per-port Link & Receive),
FDX (per-port full / half-duplex mode for 10Mb ports)
       For Model 528 Fast Ethernet copper ports only:
AUTO (Auto-negotiation operation), per-port, 100 (ON for 100Mb/s 
speed), 10 (ON for 10Mb/s speed),  F/H (Full- or Half-Duplex, ON for 
full-duplex, OFF for half-duplex).  No AUTO for Model 528F Fiber ports
Operating Environment
Ambient Temperature:  32
°
 to 120
°
 F (0
°
 to 50
°
C)
Storage Temperature:   -20
°
to 60
°
C
Ambient Relative Humidity:  10% to 95% (non-condensing)
Packaging
Enclosure:   High strength metal.  Suitable for wiring closet shelf, 
desktop, or vertical / wall mounting (brackets included)
Dimensions:  9.55 in D x 8.5 in W x 1.3 in H (24 cm x 22cm x 3.3 cm)
Weight:
2.5 lb. (1.15 Kg)
Cooling method:  Fan cooled, @ 9 cfm
Power Supply (Internal)
AC Power Connector:  IEC-type, male recessed, rear of chassis
Input Voltage:      90 to 260 VAC (auto-ranging)
Input Frequency:  47 to 63 Hz (auto-ranging)
Power Consumption: 10 watts typical, 20 watts P.S. rating
 
Agency Approvals
UL listed (UL1950), cUL, CE
Emissions meet FCC Part 15 Class A
Warranty
Three years, return to factory
Made in USA