ZyXEL Communications XGS-4526 User Manual

Page of 491
Chapter 49 Cluster Management
XGS-4526/4528F/4728F User’s Guide
440
49.3  Clustering Management Configuration  
Use this screen to configure clustering management. Click Configuration from 
the Cluster Management screen to display the next screen.
Figure 238   Management > Clustering Management > Configuration 
The following table describes the labels in this screen. 
Table 165   Management > Clustering Management > Configuration 
LABEL
DESCRIPTION
Clustering 
Manager
Active
Select Active to have this Switch become the cluster manager switch. 
A cluster can only have one manager. Other (directly connected) 
switches that are set to be cluster managers will not be visible in the 
Clustering Candidates list. If a switch that was previously a cluster 
member is later set to become a cluster manager, then its Status is 
displayed as Error in the Cluster Management Status screen and a 
warning icon (
) appears in the member summary list below.
Name
Type a name to identify the Clustering Manager. You may use up to 
32 printable characters (spaces are allowed).
VID  
This is the VLAN ID and is only applicable if the Switch is set to 
802.1Q VLAN. All switches must be directly connected and in the 
same VLAN group to belong to the same cluster. Switches that are not 
in the same VLAN group are not visible in the Clustering Candidates 
list. This field is ignored if the Clustering Manager is using Port-
based
 VLAN.