ZyXEL Communications GS-1548 User Manual

Page of 170
 Chapter 19 RMON-Lite
GS-1524/GS-1548 User’s Guide
127
19.5  RMON Alarm: Overview 
Use the RMON Alarm: Overview screen to view configured alarms that occur when the 
sampled data exceeds the specified threshold. To open this screen select [3] Alarm in the 
RMON MIB Table: drop down list box in the RMON-Lite screen.
Figure 80   RMON Alarm: Overview.
The following table describes the labels in this screen.    
Utilization (%)
This field displays the utilization as a percentage of maximum utilization allowed on 
the port in this polling sample.
History 
Statistics 
Overview
Click this to go back to the RMON History Statistics: Overview screen.
Table 59   RMON History Statistics: Control (continued)
LABEL
DESCRIPTION
Table 60   RMON Alarm: Overview
LABEL
DESCRIPTION
RMON MIB 
Table:
Use this drop down list box to select the MIB table you want to view. Click Apply to 
refresh the screen to the selected MIB table view. 
Refresh
Click this to update all the fields in the RMON Alarm: Overview screen.
Create new 
Alarm
Click this to view the RMON Alarm: Create New Alarm screen where you can 
configure the parameters for an alarm.
Index
This field displays the alarm configuration index number. Click this number to edit 
the alarm entry.
Interval (sec)
This field displays the time interval (in seconds) between data samplings.
Variable
This field displays the name of the MIB field whose data is to be sampled.
Sample Type
This field displays the method of obtaining the sample value (absoluteValue or 
deltaValue).
Value
This field displays the value of the statistic during the last sampling period. This 
value is for comparing against the RisingThreshold and FallingThreshold values.
Startup Alarm
This field displays the alarm type (1:rising2:falling, or 3:risingOrFallingAlarm
that can be sent when this alarm is first activated.
RisingThreshold
This field displays the rising threshold value set up for this alarm.