ZyXEL Communications GS-1548 User Manual

Page of 170
 Chapter 19 RMON-Lite
GS-1524/GS-1548 User’s Guide
129
The following table describes the labels in this screen.
19.6  RMON Event: Overview 
Use the RMON Event: Overview screen to view and delete event entries configured on the 
Switch. Select [9] Event from the RMON MIB Table: drop down listbox in the RMON-Lite 
screen to view the screen as shown.
Figure 82   RMON Event: Overview.
Table 61   RMON Alarm: Create New Alarm
LABEL
DESCRIPTION
RMON MIB 
Table:
Use this drop down list box to select the MIB table you want to view. Click Apply to 
refresh the screen to the selected MIB table view. 
Index
This field displays the index number of this alarm entry.
Interface
Select the port which is monitored for this alarm.
Counter
Select the data which is used to test if this alarm is triggered, the choices are Drop 
EventsOctetsPackets and so on.
Sample Type
Select the method of obtaining the sample value. Choices are Absolute and Value.
Startup Alarm
Select the startup alarm type (Rising ThresholdFalling ThresholdRising Or 
Falling Threshold).
Rising 
Threshold
Specify a rising threshold (between 0 and 2147483647). When a value is greater or 
equal to this threshold, the probe triggers an alarm.
Falling 
Threshold
Specify the falling threshold (between 0 and 2147483647). When a value is smaller 
or equal to this threshold, the probe triggers an alarm. 
Rising Event 
Select an index number of a rising event.
Falling Event
Select an index number of a falling event.
Owner
Enter a descriptive name of the application that creates this entry. You can use 1-64 
printable ASCII characters. Spaces are not allowed.
Apply
Click this to save the settings to the Switch.
Alarm Overview Click this to go back to the RMON Alarm: Overview screen.