Allied Telesis GS900/5E User Manual

Page of 40
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide
25
Planning the Installation
Table 3 contains the cabling specifications for the twisted pair ports.
Note
The twisted pair ports on the switch feature Auto-MDI when 
operating at either 10, 100, or 1000 Mbps. Each port is individually 
configured as MDI or MDI-X when connected to an end-node. 
Consequently, you can use either a straight-through or crossover 
twisted pair cable when connecting any network device to a twisted 
pair port on the switch. For example, a port operating at 10 or 100 
Mbps uses two pairs of twisted pair wiring while a port operating at 
1000 Mbps uses four pairs of twisted pair wiring.
Table 3. Twisted Pair Cabling and Distances
Speed
Type of Cable
Maximum 
Operating 
Distance
10 Mbps
Category 3 or better 100-ohm 
shielded or unshielded twisted pair 
cable
100 m (328 ft)
100 Mbps
Category 5 or Category 5E 
(Enhanced) 100-ohm shielded or 
unshielded twisted pair cable
100 m (328 ft)
1000 Mbps
Category 5 and Category 5E 
(Enhanced) 100-ohm shielded or 
unshielded twisted pair cable
100 m (328 ft)