Fujitsu V6.00 User Manual

Page of 174
ServerView Event Manager
 139
Trap overview
5.3.18 ServerControl traps (SC2.mib)
MIB-OID: 1.3.6.1.4.1.231.2.10.2.2.10.20
This section lists ServerControl traps in alphabetical order.
Trap name
 ID
Meaning
Error class
sc2TrapAcFail
2040 Mains failed in the specified 
cabinet. This trap occurs 
only in storage extension 
cabinets without UPS or 
BBU. A server has no time 
to send this trap.
critical
sc2TrapBatteryVoltage
Prefail
2054 Battery is predicted to fail.
major
sc2TrapBiosSelftest
Error
2005 A critical error occurs while 
BIOS selftest. Take notice 
of this error to clear the 
error condition.
critical
sc2TrapBootMessage
LogEntry
2102 An error message was 
written into the 
systemboard's message 
log. This could have 
happened when an error 
occurred before the server 
management agents were 
running or any error without 
a specific trap. See server 
management message log 
for detailed error 
description.
major
sc2TrapBootRetryCount
Zero
2095 This trap will be sent when a 
boot retry counter gets zero 
on power up.
major
Table 41: ServerControl traps (SC2.mib)