Fujitsu V6.00 User Manual

Page of 174
ServerView Event Manager
 141
Trap overview
sc2TrapDcFail
2041 DC power failed in the 
specified cabinet. 
This is the result of the 
systems power-good 
sensor monitoring. The 
system stops if this error 
occurs.
critical
sc2TrapFanAdded
2010 The indicated hot-plug fan 
was inserted.
informational 
sc2TrapFanCritical
2013 The indicated fan became 
critical.
major
sc2TrapFanFailed
2014 The indicated fan failed.
critical 
sc2TrapFanOk
2012 The indicated fan is OK 
again.
informational 
sc2TrapFanRemoved
2011 The indicated hot-plug fan 
was removed.
informational
sc2TrapIntrusionAsserti
on
2110 The front door or housing 
was opened.
major
sc2TrapIntrusionChang
ed
2112 The front door or housing 
was opened or closed.
major
sc2TrapIntrusionDeass
ertion
2111 The front door or housing 
was closed.
informational
sc2TrapMemErrorModul
eFailing
2069 A memory module failed.
major
sc2TrapMemErrorModul
ePrefail
2068 A memory module is 
predicted to fail (prefailure).
major
sc2TrapMemErrorModul
eReplaced
2070 A memory module failed 
and was replaced by a hot-
spare module.
major
Trap name
 ID
Meaning
Error class
Table 41: ServerControl traps (SC2.mib)