Fujitsu V3.1.0 User Manual

Page of 233
User ID
Enter the user ID to use to control VM management software.
Password
Enter the password for VM management software.
3.
Click <OK>.
VM management software settings are changed.
9.6  Changing Power Monitoring Environment Settings
This section explains how to change power monitoring environment settings.
Power environment settings include environmental data settings, collection cancel settings, and power monitoring device settings.
9.6.1  Changing Environmental Data Settings
Use the following procedure to change environmental data settings:
1.
Select [Tools]-[Options] from the ROR console menu.
The [Options] dialog is displayed.
2.
Click the [Environmental Data] category title, and input the following items in the displayed area.
Data to collect
Select the [Power] checkbox to start collecting power consumption data.
Polling interval (in minutes)
Enter the time interval of the data collection (1-6 or 10).
The number of devices that can be monitored simultaneously depends on the value of this polling interval and the load put on
the admin server. The following values are guidelines.
 
Table 9.1 Polling Interval
Polling Interval
Number of Devices that can be Monitored Simultaneously
5 minutes
Up to 40 devices
10 minutes
Up to 60 devices
Use a polling interval of 5 minutes or longer when monitoring chassis and servers. Use a polling interval of 10 minutes if
monitoring more than 40 devices.
Data storage period
Enter storage periods for each collection rate. Data older than the configured storage period will be deleted every day.
Enlarging data storage periods reduces the number of devices that can be monitored simultaneously.
Use the default storage period values when monitoring chassis and servers.
3.
Click <Apply>.
The new settings are applied.
 
 Note
If the [Power] checkbox under [Data to collect] is cleared, the collection of power consumption data (including the calculation of hourly,
daily, and other summarized data) will not be performed anymore.
9.6.2  Canceling Collection Settings for Power Monitoring Environments
This section explains how to cancel the collection of power consumption data.
- 78 -