Fujitsu BX600 S2 User Manual

Page of 173
PRIMERGY BX600 S2 Basic Unit
 55
Preparation for Use and Operation
Management Blade Configuration
5.3
Management Blade Configuration
The two redundant management blades provide functionality for remote control 
of the PRIMERGY BX600 S2 base unit over the LAN (see 
“ 
manual). To commission the base unit, the LAN parameters of the management 
blades must be set using a local client computer. 
To configure the management blade, follow the steps listed below.
Pre-Configuration Requirements
The procedures that follow assume that the basic unit is connected to the power 
line.
Cabling the System
Ê
Connect the serial interface of the client (COM1) to the serial interface of the 
master management blade using an RS232 cable (null modem cable). 
I
The master management blade is indicated by a green LED (see 
).
Initial Configuration via Serial Connection to Client
Ê
Open a HyperTerminal session from the client to the master management 
blade. Use the following settings:
Bits per second
115200
Data bits
8
Parity None
Stop bit
1
Flow control
None
Terminal type
VT100