Polycom 1725-36031-001 User Manual

Page of 51
SpectraLink 8000 SVP Server: Administration Guide for Mitel and Cisco 
PN: 1725-36031-001_H.doc 
22 
Connect SVP Server to LAN 
Using a Cat. 5 cable, connect the 
NETWORK
 port on the SVP Server to 
the connecting port on the Ethernet switch. 
Connect power 
1.  Once the units have been properly grounded, connect the power 
plug from the AC adapter to the jack labeled 
PWR
 on the SVP 
Server.  
 
Use only the provided Class II AC Adapter with output 24V DC, 1A. 
2.  Plug the AC adapter into an 110VAC outlet to apply power to the 
SVP Server. 
3.  Verify that leakage current ("touch" current) is below 250 μA rms 
on exposed metal surfaces. 
4.  If leakage is excessive, power off the system and re-verify ground 
path continuity. 
5.  The system will cycle through diagnostic testing and the LEDs 
will blink for about one minute. When the system is ready for use: 
— 
The 
ERROR
 LED should be off. 
—  Status 1
 should be blinking.