ActivMedia Robotics 
802.11b-compatible wireless Ethernet card in one of its slots.  The wireless Ethernet 
antenna sits atop the top deck. 
To complete the wireless installation, you will need to provide an Access Point module 
(comes  as  an  accessory  with  most units).    Attach the Access Point to one of your LAN 
hubs or switches with a standard CAT5 100Base-T cable.  No configuration required.  We 
use the default operating mode:  “managed” client-server. 
We ship installed PC systems’ preset and tested at a fixed IP address with Class-C network 
configuration.  We allocate the same IP to both the wired and wireless Ethernet ports, 
typically 192.168.1.32.  Although you need not fuss with drivers or low-level device 
settings, before you may establish a network connection with the onboard PC (not the 
robot’s controller!), even if just through a “cross-over” Ethernet cable to another PC, 
you’ll need to reconfigure the robot’s PC network settings.  Please consult with your 
network systems administrator for networking details. 
Briefly, with Windows, go to the Control Panel’s Network and Dialup Connections 
wizard and choose the networking device’s Properties to change the IP address and 
other details.  Under Linux, there are similar, GUI-based tools under X-Windows to help 
you set up the network, such as netcfg, but we prefer to edit (emacs or vi) the salient 
network settings in /etc/sysconfig/network and in the specific device configuration 
files found in  /etc/sysconfig/network-scripts/, such as ifcfg-eth0 (wired 
Ethernet) and ifcfg-eth1 or ifcfg-wvlan0 (wireless).  
From Windows, use the Control Panel Network and Dialup Connections tool to 
enable  or  disable  a  particular  device.    From  Linux,  use  ifup and ifdown to enable or 
disable an Ethernet device.  For example, as superuser, type ‘ifdown eth0; ifup 
eth1’ to switch from a tethered to a wireless Ethernet connection. 
For remote connections over Ethernet to your onboard PC, simply use telnet or the more 
secure  ssh to log in to your Linux system.  Allow X-windows server connections at your 
remote PC (xhost) if you plan to export the X-Windows display from the robot PC for 
remote GUI-based controls (export DISPLAY=remote’s hostname or IP:0, for 
example). 
With Windows, you will need a special remote-control application to establish a GUI-
based connection from a remote computer to the onboard PC over the network; 
VNCserver, for example, or XWin32
Please note that you may not connect with the robot’s microcontroller directly over the 
network:  That is, you cannot run a client application, such as the ARIA demo or Saphira, 
on the remote PC and choose to directly connect with the robot server by selecting the 
robot PC’s IP address.  Rather, either run the client application on the onboard PC and 
export the display and controls over the network to the remote PC (preferred), or use the 
ARIA-based IPTHRU programs (see program sources in Aria/examples) to negotiate the 
IP-to-serial conversions needed by the client-server connection. 
UPS and Genpowerd 
To protect your robot’s onboard PC data, we’ve enabled a detection scheme in AROS 
and UPS-like software on the computer that invoke shutdown of the operating system in 
the event of a persistent low-battery condition.
AROS versions 1.6 and later raises the HOST serial port's RI pin 9 to RS232-level high when 
the P2-H8 controller is operating normally, but when your robot’s battery power drops the 
                                                           
9
 The original Pioneer 2 Motor-Power boards implemented a similar strategy in hardware. 
 
21