Honeywell 1450g User Manual

Page of 206
2 - 1
2
Programming the Interface
Introduction
This chapter describes how to program your system for the desired interface.
Programming the Interface - Plug and Play
Plug and Play bar codes provide instant scanner set up for commonly used interfaces.
Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.
Keyboard Wedge
If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard, scan 
the bar code below.  Keyboard wedge is the default interface.
Note: The following bar code also programs a carriage return (CR) suffix.
Laptop Direct Connect
For most laptops, scanning the Laptop Direct Connect bar code allows operation of the scanner in parallel with the integral 
keyboard.  The following Laptop Direct Connect bar code also programs a carriage return (CR) suffix and turns on Emulate 
External Keyboard (
).
RS232 Serial Port
The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal.  The following RS232 Interface 
bar code also programs a carriage return (CR) and a line feed (LF) suffix, baud rate, and data format as indicated below.  It also 
changes the trigger mode to manual.
Option
Setting
Baud Rate
115,200 bps
Data Format
8 data bits, no parity bit, 1 stop bit
IBM PC AT and Compatibles with 
CR suffix
Laptop Direct Connect
with CR suffix
RS232 Interface