OmniTek 2.3 User Manual

Page of 128
OmniTek XR User Guide, Software Release 2.3 
Page 17 
Engineering Options 
The Engineering options allow the current Engineering Settings to be saved in .ode files 
and to be subsequently re-loaded. The layout of the windows and toolbars is unaffected 
by saving and loading Engineering settings. 
SNMP Settings 
This option controls the program’s configuration for SNMP. This is only required as part of 
the logging package. Consequently details of SNMP configuration are given alongside 
the description of the logging facility, which starts on page 104. 
Look & Feel Options 
The first of these options calls up a configuration dialogue that lets you specify the 
colours in which certain display items are shown. These settings can then be saved and 
loaded as ‘presets’, which can then be used to copy the user setup from one system to 
another. 
Analyzer Menu 
The Analyzer menu provides control of OmniTek XR’s waveform monitor function. 
Some features can only be controlled from this menu, however the most 
commonly used functions are also accessed from icons on the toolbars. 
Note:
 The precise range of options seen depends on the details of the system 
being used. 
 
 
Input to Analyzer 
This option controls whether the Analyzer looks at the serial input or at the Generator 
output. Note: This control is only available where the system includes the Motion-Capture 
option. This control can also be changed from the ‘Source’ toolbar. 
Interpolator 
This option enables an interpolation filter that controls how the hardware samples and 
displays the incoming data. It is usually left enabled but occasionally a clearer result can 
be obtained by turning the interpolator off. 
Low Pass 
This turns on/off a low-pass filter. The frequency response is complaint with EBU 
Technical Recommendation R103-2000 and changes depending on whether the current 
video format is SD or HD. 
TRS Pass 
This control lets you enable the display of TRS data which, by default, is not displayed in 
the Mini-Pic, Waveform or Vector Scope windows. 
Note that the data shown in the Data View window will always contain the TRS data 
present on the signal, regardless of the state of this control. 
Closed Caption Source 
Closed caption data and certain types of teletext subtitles can be detected within the 
serial input, decoded and displayed in the Closed Caption window (see page 44). These 
captions may also be displayed in the Mini-Pic window (see page 51) and written to an 
XML log file (see page 31).  
Line 21 and EIA-608 closed captions and OP-47 teletext subtitles are supported as 
standard. Where OmniTek XR includes the 708 Decode option, EIA-708 captions can 
also be displayed.  
Note:
  This option just selects the type of caption to be displayed. Additional information is 
required where teletext is to be displayed and where ‘Line 21’ captions delivered in video