Hoshizaki FD-1001MWH(-C) User Manual

Page of 44
7
1. Icemaker
• If you would like to convert to top water supply, install the optional Top Water Supply Kit 
(HS-13).
• Icemaker water supply inlet is 1/" female pipe thread (FPT). A minimum of 3/8" OD 
copper tubing is recommended for the icemaker water supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" OD hard pipe is recommended for 
the icemaker drain line.
-inch 
(5-cm) air 
gap
Floor
Drain
FD-1001MAH(-C)
FD-1001MRH(-C)
FD-1001MLH(-C)
Separate piping to approved drain. 
Leave a -inch (5-cm) vertical air 
gap between the end of each pipe 
and the drain.
Icemaker Water 
Supply Line 
Shut-Off Valve
Icemaker Water 
Supply Line
Drain Valve
Icemaker
Icemaker Water 
Supply Inlet
1/" FPT
Bin Drain Outlet 
3/4" FPT
Icemaker 
Drain Outlet 
3/4" FPT
To convert to top water supply, 
install the optional Top Water 
Supply Kit (HS-13).
Storage Bin
Fig. 14