b) Connection to a Closed Loop System
• Condenser water supply inlet is 1/" female pipe thread (FPT). A minimum of 3/8" OD 
copper tubing is recommended for the condenser water supply line.
• Condenser return outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for 
the condenser return line.
• Shut-off valves and drain valves should be installed at both the condenser water supply 
inlet and condenser return outlet.
• The water supply to the condenser should not drop below 4 GPM. 
• The pressure differential between the condenser water supply inlet and condenser return 
outlet must be no less than 10 PSIG.
• When using a glycol blend, the solution mixture should be less than 30% glycol.
• In order to maintain the proper high side pressure, the condenser water supply inlet 
temperature should not drop below 45°F (7°C) and the condenser return outlet 
temperature must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker 
installation is complete, confirm the condenser return outlet temperature 5 minutes 
after a freeze cycle starts. If the outlet temperature is not in the proper range, adjust the 
water-regulating valve to bring it into range.
FD-1001MWH(-C)
Condenser 
Connection to 
a Closed Loop 
Water Supply
Separate piping to approved drain. 
Leave a -inch (5-cm) vertical air gap 
between the end of each pipe and the 
drain.
-inch 
(5-cm) air 
gap
Floor
Drain
Condenser Water 
Supply Inlet
1/" FPT
Condenser 
Return Outlet 
3/8" FPT
Icemaker Water 
Supply Line 
Drain Valve
Icemaker
Icemaker Water 
Supply Inlet
1/" FPT
Bin Drain Outlet 
3/4" FPT
Icemaker 
Drain Outlet 
3/4" FPT
To convert to top water supply, 
install the optional Top Water 
Supply Kit (HS-13).
Storage Bin
Fig. 16
Condenser Shut-Off Valves
Condenser Drain Valves
Icemaker Water 
Supply Line 
Shut-Off Valve