Tandberg Data T40 User Manual

Page of 95
 
StorageLibrary Installation and User Guide 
71 
The following components of the library have LEDs: 
 
Library 
 
Ethernet status LED 
The Maintenance Menus 
Table 7. Maintenance Menus - Item Name and Description 
Item name 
Description 
Library FW upgrade 
Upgrades the library FW through RMI 
Prepare to Ship 
When selected, the robotics is positioned for installing the transport locking 
screws. 
The magazines are ejected to facilitate the installation. 
The library cannot be safely shipped with cartridges in the magazines. 
The Prepare to ship command must be run before the library is transported to 
reinstall the transport locking screws and to remove all cartridges in the 
library. 
Reboot 
Performs a hard reset of the library. 
Restore default 
Sets the library settings to their factory default values. 
Clear WEB password 
Clears the WEB password (from FPI only) 
The Diagnostics Menu 
Table 8. Diagnostics Menu - Item Name and Description 
Item name 
Description 
Capture logs 
Displays a log that contains information about library and drive configuration, 
event log and error log. This log can be saved to a file or sent via e-mail to 
technical support. 
System test 
Runs a test of the library hardware. 
Cycle test 
Starts a test where cartridges are moved randomly between magazine slots 
and between the drive and the magazines. 
Verifying Hardware 
1.  The library uses one SCSI ID for each SCSI tape drive. Verify that the drive SCSI IDs are set to 
unique SCSI IDs that are not used by any other SCSI device on the same bus. Depending on 
other devices attached to the same SCSI bus and their SCSI IDs, you may need to change the 
SCSI ID of the tape drive(s) before you can use the library. 
2.  Verify that the system recognizes the tape drives during the boot process. 
3.  Verify that the SCSI host adapter recognizes the tape drives during its initialization. 
4.  Verify that the status on the library s front panel interface is OK. 
5.  Verify that the power cable is inserted correctly. 
6.  Verify that the SCSI cables are properly connected at both ends. Check that the cables are not 
damaged, and verify the lengths of your SCSI cabling. The length of the internal SCSI cabling 
inside the library is 30cm. This length must be included in any calculation of cable length. 
7.  Verify that the SCSI bus is properly terminated. Only the devices physically at the beginning and 
end of the cable must be terminated.