 Shipping or Transporting StorageLibrary 
 
Reinserting the Transport Locking Screws 
If you need to move or ship the StorageLibrary you need to reinstall the transport locking screws to 
protect the robotics. The screws fasten the robotics to the chassis and hold the robotics in a locked 
position. Use the instructions below to reinsert the transport locking screws. 
1.  Locate the transport locking screws. They are stored in the rear of the unit and they are marked 
with red plastic tabs (four M3x6 mm screws). 
2.  From the FPI select Menu > Tools > Prepare to ship and follow the instructions displayed on the 
FPI screen. The robotics will automatically be moved to the lower front position, and the 
magazines will pop out. 
3.  Remove the magazines. 
4.  Remove all cartridges from all the magazines. 
5.  Turn off the power switch on the rear of the unit. 
6.  Install the four transport locking screws. The screws fasten the robotics to the front chassis. The 
transport locking screws are screwed into the robotics from the front of the library, two on each 
side of the front bezel. See 
Figure 25. Transport Locking Screws Marked with Red Plastic Tab
7.  If installed, remove the rack mount ears. If your library is a 24 slot version you need to remove the 
two upper magazines by using the emergency eject tool. See 
Manual/Emergency Release of
 
Magazines
 
8.  Reinsert all magazines. 
9.  If you need to ship the unit, use the original packaging.