Dell PowerVault 7x0N Systems — Connecting to ATM and FDDI Networks
The abbreviated sample output (showing unit 3 only) from this command is as
follows:
follows:
/01+2
%
3143
14#
5
*+#
6/(7
/01', &%
/01+
,&%
+
%
+
2*)%%
8#!"!
/01&',
%*2'
9 +%:;:<;:;
Interpreting the output: To verify that the ATM interface is operational, check the fol-
lowing items:
lowing items:
The
UNI configured version
and
UNI operating version
. This
value should be 3.1 in both cases.
The
SSCOP operational state
. This should indicate that the UNI is oper-
ational. If you see inoperational instead, the ATM card is improperly connected to
the network or the switch is improperly configured.
the network or the switch is improperly configured.
The
Primary ATM address
. This should be a valid ATM address for your
network. If you see an address consisting entirely of zeros, the ATM card is either
improperly connected to the network, or there might be a configuration problem.
improperly connected to the network, or there might be a configuration problem.
$"
$
For the filer to participate in an ELAN, you must configure the ATM adapter with the
address of the LECS. The LEC joins an ELAN by first exchanging configuration infor-
mation with the LECS. The LECS then supplies the client with the ATM address for
the LES.
address of the LECS. The LEC joins an ELAN by first exchanging configuration infor-
mation with the LECS. The LECS then supplies the client with the ATM address for
the LES.
To configure the LECS address, perform the following steps:
1.
Set the LECS address.
2.
Check that the adapter is communicating with the LECS.