Agilent Technologies E4445A User Manual
242
Chapter 4
Instrument Functions: P - Z
SWEEP
In
st
ru
m
e
nt
Funct
ions
:
P
-
Z
Default Terminator: seconds
Range:
in zero span: 1
µs to 6000s
in swept spans: 1 ms to 2000s
Remote Command:
[:SENSe]:SWEep:TIME <time>
[:SENSe]:SWEep:TIME?
[:SENSe]:SWEep:TIME:AUTO OFF|ON|0|1
[:SENSe]:SWEep:TIME:AUTO?
Example:
SWE:TIME 500 ms
SWE:TIME:AUTO OFF
4.7.2
Sweep
Switches the analyzer between continuous-sweep and single-sweep mode. Pressing the
front-panel Single key will also put the analyzer in single-sweep mode, then take a sweep.
front-panel Single key will also put the analyzer in single-sweep mode, then take a sweep.
Key Path:
Sweep
State Saved:
Saved in instrument state
Factory Preset: Continuous
Remote Command:
:INITiate:CONTinuous OFF|ON|0|1
:INITiate:CONTinuous?
:INITiate:[IMMediate]
Remote Command Notes: This command affects sweep if not in a measurement, and
affects trigger when in a measurement. A “measurement” refers to any of
the functions under the
the functions under the
MEASURE
key. This corresponds to continuous
sweep or single sweep operation when not in a measurement, and
continuous measurement or single measurement operation when in a
measurement.
continuous measurement or single measurement operation when in a
measurement.
When NOT in a measurement, this command does the following:
•
When ON at the completion of each sweep cycle, the sweep system
immediately initiates another sweep cycle.
immediately initiates another sweep cycle.
•
When OFF, the sweep system remains in an “idle” state until
CONTinuous is set to ON or an :INITiate[:IMMediate] command is
received. On receiving the :INITiate[:IMMediate] command, it will go
through a single sweep cycle, and then return to the “idle” state.
CONTinuous is set to ON or an :INITiate[:IMMediate] command is
received. On receiving the :INITiate[:IMMediate] command, it will go
through a single sweep cycle, and then return to the “idle” state.