SWEEP
In
st
ru
m
e
nt
Funct
ions
:
P
-
Z
The query returns 1 or 0 into the output buffer. 1 is returned when
there is continuous sweeping. 0 is returned when there is only a single
sweep.
When in a measurement, this command does the following:
When ON at the completion of each trigger cycle, the trigger system
immediately initiates another trigger cycle.
When OFF, the trigger system remains in an “idle” state until
CONTinuous is set to ON or an :INITiate[:IMMediate] command is
received. On receiving the :INITiate[:IMMediate] command, it will go
through a single trigger cycle, and then return to the “idle” state.
The query returns 1 or 0 into the output buffer. 1 is returned when
there is continuous triggering. 0 is returned when there is only a single
trigger.
Use the :TRIGger[:SEQuence]:SOURce command to select the trigger
source.
Example:
INIT:CONT OFF
4.7.3
Auto Sweep Time
Switches the analyzer between normal and accuracy sweep states. Provides you the ability
to select the rules for the control of sweep time when
Sweep Time
is set to
Auto
. Setting
Auto
Sweep Time
to
Accy
will result in slower sweep times, usually about three times as long, but
better amplitude accuracy for CW signals. The instrument specifications only apply when
Sweep Time
is set to
Auto
, and
Auto Sweep Time
is set to
Accy
.
Additional amplitude errors occur when
Auto Sweep Time
is set to
Norm
are usually well
under 0.1 dB, though they are not guaranteed. Because of the faster sweep times and still
low errors,
Norm
is the preferred setting of
Auto Sweep Time
. Also, when the
Auto All
function
is performed,
Auto Sweep Time
is set to
Norm
.
Key Path:
Sweep
Key Notes:
Greyed out in Zero Span and FFT, but still shows user selected states
(Norm or Accy). Goes to Norm on Auto All.
Dependencies/
Couplings:
Key is greyed out in Zero Span and FFT, but still shows user selected
states (Norm or Accy). Goes to Norm on Auto All.
State Saved:
Save
Factory Preset: Norm
Remote Command:
[:SENSe]:SWEep:TIME:AUTO:RULes NORMal|ACCuracy
[:SENSe]:SWEep:TIME:AUTO:RULes?