System Verification 
40
312359J
System Verification
Graco recommends running the following tests daily.
Mix and Integration Tests
Use the following tests to check for proper mix and inte-
gration.
Butterfly Test
At low pressure, normal flow rate, and without a spray tip 
installed, dispense a 1/2 in. (12.7 mm) bead of material 
onto foil until multiple changeovers of each pump have 
occurred. Fold the sheet of foil over the fluid then peel it 
back and look for unmixed material (appears mar-
ble-like).
Curing Test
Spray a single continuous pattern on foil at typical pres-
sure setting, flow rate, and tip size until multiple change-
overs of each pump have occurred. Trigger and 
de-trigger at typical intervals for the application. Do not 
overlap or cross over your spray pattern. 
Check curing at various time intervals, listed on the 
material data sheet. For example, check for dry to touch 
by running your finger along the test pattern’s entire 
length at the time listed on the data sheet.
NOTE: 
Spots that take longer to cure indicate insufficient inte-
gration.
Appearance Test
Spray material onto metal substrate. Look for variations 
in color, gloss, or texture that may indicate improperly 
catalyzed material.
Pump and Metering Test
This test checks the following four items and should be 
run every time a new job is started, or if there is a sus-
pected problem.
Verifies that the pumps installed match the pumps 
selected on the Setup screen by dispensing exactly 
750 ml of each material.
Verifies that each pump holds fluid against the pump 
inlet valve by stalling on the down stroke.
Verifies that each pump holds fluid against the pump 
piston valve and packings by stalling on the 
upstroke.
Verifies that each metering valve holds fluid, and 
that there are no external leaks between the pump 
and metering valve.
Verifies that the recirculation valves (AC, AD) are 
closed and do not leak.
This test will dispense 750 ml of component A, and then 
750 ml of component B. Dispense into separate cups so 
the fluid can be returned to the supply tanks. 
NOTE: 
During each dispense the flow will stop once to stall the 
upstroke, once to stall the downstroke, and then it will 
finish the dispense. Do not close the sampling valve until 
the third flow stops and the blue pump light (DK) goes 
out.
1.
Enter Test mode in the run (fluid control) screen. 
 
to 
run pump test.