System Verification 
42
312359J
b.
Slowly open and adjust sampling valve B to 
achieve desired flow. Pump stops automatically; 
twice during test and again when dispense 
completes. Pump B light (DK) turns off.
c.
Close sampling valve B (AF).
6.
Compare fluid amounts in containers; they should 
be equal at 750 ml (25.3 fl. oz.) each. Repeat test if 
fluids are not equal. If problem persists, see Alarm 
Codes and Troubleshooting
, page 52
.
7.
Return fluid used in test to corresponding fluid sup-
ply container.
Confirm Pump Test
The Confirm Pump Test screen displays when the pump 
test completes without error. This screen displays the 
target volume of material dispensed into each beaker 
from each pump.